Product Type:
LXSG-15S-25S Multi Jet Dry Dial Plastic Water MeterRemark:APPLICATION:
>> Measuring the volume of cold potable water passing through the pipeline.
FEATURES:
>> Completely plastic shell, solid and robust design, long service guaranteed.
>> High quality materials corrosion resistance.
>> Pole ring magnet polymer coating as protection against deposits.
>> The measuring mechanism can be exchanged.
>> Anti-magnet.
>> Inside calibration device.
>> Large measuring range high flow accuracy.
>> Steady curve characteristics.
>> Measuring accuracy is up to ISO4064, Class B.
>> Overload flowrate: Qs=2Qp (Qn=nominal flowrate)
WORKING CONDITION:
>>Water temperature: <=40•C
>>Water pressure: <=1.0MP(10bar)
MAXIMUM PERMISSIBLE ERROR:
>>In the lower zone from qmin inclusive up to but excluding qt is +-5%
>>In the upper zone from qt inclusive up to and including qs is +-2%
ACCESSORIES
Optional: Both brass thread connections and plastic thread connections are available.
| Type |
Meter size |
Class |
Overload flow qs |
Nominal Flow qp |
Transitional Flow qt |
Min Flow qmin |
Min Reading |
Max Reading |
| MM |
M3/h |
M3 |
| LXSG-20S |
20 |
A |
5 |
2.5 |
0.250 |
0.100 |
0.0001 |
9,999/99,999 |
| B |
0.200 |
0.050 |
AXIMUM PERMISSIBLE ERRORA)in the lower zone from qmin
inclusive up to but excluding qt is+-5%
B)in the upper zone from qt
inclusive up to and including qs is+-2%
Meter Size |
Length(L) |
Width(B) |
Height(H) |
Connecting Therad |
Weight |
| MM |
MM |
D |
d |
kg |
| 15 |
165 |
99 |
108 |
G3/4B |
R1/2 |
0.53 |
Flow Error Curve
Head Loss Curve