Product Type:
LXSG-15E-50E ROLLING WING DRY WATER METERRemark: APPLICATION:
This range of water meter is used to measure the total quantity of cold potable water which consumed in houshold or a resident unit, passing through the pipeline.
FEATURES:
This is a dry-type water meter.Its counting and measuring devices are driven by magnetic coupling. It is characterized by easy reading,good antifreezing property and ability to permanently keep the reading clear.
WORKING CONDITION:
Water temperature:<=40
•C Water pressure:<=1MPa
COMPLIANCE WITH STANDARD: ISO 4064 (GB/T778-1996)
INDICATING ERROR:
At low zone is+-5% from minimum flow rate(qmin)to transitional flow rate(qt)exclusive boundary
At high zone is+-2% from transitional flow rate(qt) to overload flow rate(qs)
| Type |
Meter Size |
Class |
Overload Flow qs |
Nominal Flow qp |
Transitional Flow qt |
Min Flow qmin |
Min Reading |
Max Reading |
|
Mm |
M³/h |
m³ |
| LXSG-15E |
15 |
A |
3 |
1.5 |
0.150 |
0.060 |
0.0001 |
9,999/99,999 |
| B |
0.120 |
0.030 |
|
LXSG-20E |
20 |
A |
5 |
2.5 |
0.250 |
0.100 |
0.0001 |
9,999/99,999 |
| B |
0.200 |
0.050 |
|
LXSG-25E |
25 |
A |
7 |
3.5 |
0.350 |
0.140 |
0.0001 |
9,999/99,999 |
| B |
0.280 |
0.070 |
|
LXSG-40E |
40 |
A |
20 |
10 |
1.000 |
0.400 |
0.001 |
99,999 |
| B |
0.800 |
0.200 |
|
LXSG-50E |
50 |
A |
30 |
15 |
4.500 |
1.200 |
0.001 |
99,999 |
| B |
3.000 |
0.450 |
AXIMUM PERMISSIBLE ERRORA)in the lower zone from qmin
inclusive up to but excluding qt is+-5%
B)in the upper zone from qt
inclusive up to and including qs is+-2%
| Meter Size |
Length(L) |
Width(B) |
Height(H) |
Connecting Thread |
Weight |
| mm |
mm |
D |
d |
kg |
| 15 |
165 |
99 |
108 |
G3/4B |
R1/2 |
1.4 |
| 20 |
195 |
99 |
108 |
G1B |
R3/4 |
1.7 |
| 25 |
225 |
104 |
114 |
G1 1/4B |
R1 |
2.4 |
| 40 |
245 |
128 |
158 |
G2B |
R1 1/2 |
4.5 |
| 50 |
280 |
128 |
183 |
Connecting Flange D=160 D2=125 4-M16 |
12 |
Flow Error Curve
Head Loss Curve