Product Type:
LXH-15B VOLUMETRIC ROTARY PISTON WATER METER Remark: APPLICATION:
Measuring the volume of cold potable water passing through the pipeline.
FEATURES:
1. Volumetric meter, on principle of piston rotation, complies with ISO 4064 Class C or Class D standard
2. High sensitivity, accurate measurement even at low flow rate of 4L/h.
3. Optimum accuracy and performance at all times, in any position
4. Piston adopts high quality material to ensure stable and durable performance
5. Liquid-sealed register, easy and long tem clear reading
WORKING CONDITION:
Water temperature: <=50
•C Water pressure: <=1.0MPa
COMPLIANCE WITH STANDARD: ISO 4064 (GB/T778-1996)
MAXIMUM PERMISSIBLE ERROR:
In the lower zone from qmin inclusive up to but excluding qt is +-5%
In the upper zone from qt inclusive up to and including qs is +-2%
| Type |
Size |
Class |
qs Max. Flow |
qp Nominal Flow |
qt Transitional Flow |
qmin Min.Flow |
Start-up Flow |
Min .Reading |
Max. Reading |
| Mm |
m³/h |
L/h |
m³ |
| LXH-15B |
18 |
C |
3 |
1.5 |
22.5 |
15 |
4 |
0.0001 |
9.999 |
|
D |
17.25 |
11.25 |
AXIMUM PEMISSBLE ERROR:
- in the lower aone from qmin
inclusive up to but excluding qt is+-5%
- in the upper aone from qu
inclusive upto and including qs is +-2% DIMEENSIONS AND WEIGHT
| Type |
Size |
Lenght |
Width |
Connecting Thread |
Weight |
| MM |
D |
kg |
| LXH-15B |
18 |
115 |
¦µ88 |
G3/4B |
0.85 |
Flow Error Curve
Head Loss Curve